SFAH-5U-Q6S-PNLK-PNVBA-L1 (8058467) flow sensor

Item number:

OT-FESTO072684

pcs
Properties
Per­mis­sion RCM mark,
c UL us - Listed (OL)
CE cer­tifi­cate (see de­c­la­ra­tion of con­for­mity) acc. to EU-​EMV Di­rec­tive,
acc. to EU-​RoHS Di­rec­tive
KC-​mark KC-​EMV
Cer­ti­fied award­ing point UL E322346
Ma­te­r­ial in­for­ma­tion RoHs com­pli­ant
Mea­sured pa­ra­me­ter Mass flow,
Vol­ume flow rate
Flow di­rec­tion Uni-​directional
Mea­sure­ment prin­ci­ple Ther­mic
Mea­sure­ment process Heat Trans­fer
Flow mea­sure­ment range start­ing value [l/min] 0,100
Flow mea­sure­ment range end value [l/min] 5,0
Op­er­at­ing pres­sure [bar] -0.9 to 10
Op­er­at­ing medium Druck­luft nach ISO 8573-​1:2010 [6:4:4],
Stick­stoff,
Argon
Medium tem­per­a­ture [°C] 0 to 50
am­bi­ent tem­per­a­ture [°C] 0 to 50
Nom­i­nal tem­per­a­ture [°C] 23
Ac­cu­racy flow value ± (2% o.m.v. + 1% FS)
Re­peata­bil­ity null point in ± %FS [%FS] 0,2
Re­peata­bil­ity clamp in ± %FS [%FS] 0,8
Tem­per­a­ture co­ef­fi­cient clamp in ± %FS/K type 0,15%FS/K
Pres­sure de­pen­dency clamp in ± %FS/bar [%FS/b.] 1
Con­trol out­put 2 x PNP or 2 x NPN switch­able
Switch func­tion Win­dow com­para­tor,
Thresh­old com­para­tor,
Auto dif­fer­ence mon­i­tor­ing
Switch­ing el­e­ment func­tion Opener/closer switch­able
Max. out­put cur­rent [mA] 100
Ana­logue out­put 0 - 10 V,
4 - 20 mA,
1 - 5 V
Flow char­ac­ter­is­tic curve start­ing value [l/min] 0
Flow char­ac­ter­is­tic curve end value [l/min] 5,0
Max. load re­sis­tance cur­rent out­put [Ohm] 500
Min. load re­sis­tance volt­age out­put [kOhm] 20
Short cir­cuit re­sis­tance yes
Over­load re­sis­tant Avail­able
Re­port IO-​Link
IO-​Link, re­port De­vice V 1.1
IO-​Link, pro­file Smart sen­sor pro­file
IO-​Link, func­tion classes Teach chan­nel,
Di­ag­no­sis,
Iden­ti­fi­ca­tion,
Bi­nary data chan­nel (BDC),
Process data vari­ables (PDV)
IO-​Link, com­mu­ni­ca­tion mode COM2 (38.4 kBaud)
IO-​Link, SIO mode sup­port yes
IO-​Link, port type A
IO-​Link, process data width IN 3 Bytes
IO-​Link, process data con­tents IN 1 bit BDC (Vol­ume mon­i­tor­ing),
14 bit PDV (Flow mea­sure­ment),
2 bit BDC (Flow mon­i­tor­ing)
IO-​Link, ser­vice data unit IN 32 bit Volumen-​/Massemess­wert
IO-​Link, min­i­mum cycle time 4 ms
IO-​Link, data mem­ory needed [Byte] < 0,5 kB
Op­er­at­ing volt­age range DC [V] 22 to 26
Empty run cur­rent [mA] <= 25 mA
Re­verse po­lar­ity pro­tec­tion for all elec­tri­cal con­nec­tions
Elec­tri­cal con­nec­tion 1, con­nec­tion type Plug
Elec­tri­cal con­nec­tion 1, con­nec­tion tech­nol­ogy Wiring di­a­gram L1J
Elec­tri­cal con­nec­tion 1, num­ber of pins / wires 4
Fas­ten­ing type With Ac­ces­sories
in­stal­la­tion po­si­tion ar­bi­trary
Pneu­matic con­nec­tion For hose ex­te­rior di­am­e­ter 6 mm
Pneu­matic con­nec­tion, con­nec­tion out­let straight
Prod­uct weight [g] 60
Hous­ing ma­te­r­ial PA re­in­forced
From medium con­tact­ing ma­te­ri­als NBR,
high-​alloyed stain­less steel,
PA re­in­forced,
Alu wrought alloy, an­odised,
Epoxy resin,
Sil­i­con,
Sil­i­con ni­tride
Dis­play type Il­lu­mi­nat­ing LCD Mul­ti­ple
Pre­sentable unit(s) g,
g/min,
l,
l/h,
l/min,
scft,
scft/h,
scft/min
Set­ting op­tions IO-​Link,
Teach-​In,
über Dis­play und Tas­ten
Tamper-​proof fuse IO-​Link,
PIN code
Pro­tec­tion cat­e­gory IP40
Pres­sure drop [mbar] < 5 mbar
Pro­tec­tion class III
Cor­ro­sion re­sis­tant class KBK 2 - mod­er­ate cor­ro­sion stress
Further information on OT-FESTO072684
Weight 60 g / pcs
Customs duty number 90268020
Manufacturer Festo
Documents

 
All data are to be understood as non-binding reference values! We do not assume liability for any data selection not confirmed in writing. Unless otherwise specified, pressure values refer to liquids from Group II at +20°C.
Immediately available